Sign in →

Test Code SCCTV Chlamydia trachomatis, Self-Collect, Amplified RNA, Vaginal


Specimen Required


Only orderable as part of a profile. For more information see SCCGV / Chlamydia trachomatis and Neisseria gonorrhoeae, Self-Collect, Amplified RNA, Vaginal.

 

Specimen Type: Vaginal

Supplies: Aptima Vaginal Swab Self-Collection Kit (T1001)

Container/Tube: Aptima Multitest Swab

Specimen Volume: Swab

Collection Instructions:

1. Specimens must be collected in a healthcare setting by the patient using the Aptima Multitest Swab (provided in T1001 or available separately).

2. Provide patient with the Aptima Vaginal Swab Self-Collection Kit or Aptima Multitest Swab and collection instructions.

3. Instruct patient to collect the specimen following the instructions provided with the kit and then return swab to the healthcare professional once complete.

4. Once patient returns the specimen, ensure the tube is securely capped, and label tube with patient's entire name and collection date and time.

5. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred) and transport within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for up to 12 months.


Secondary ID

621938

Useful For

Detecting Chlamydia trachomatis using vaginal swabs collected by the patient in a healthcare setting

 

This test is not intended for use in medico-legal applications.

 

This test is not useful for the detection of other Chlamydia species.

Method Name

Only orderable as part of a profile. For more information see SCCGV / Chlamydia trachomatis and Neisseria gonorrhoeae, Self-Collect, Amplified RNA, Vaginal.

 

Transcription-Mediated Amplification

Reporting Name

C trach, RNA, SelfCollect, Vagina

Specimen Type

Varies

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) APTIMA VIAL
  Ambient  APTIMA VIAL
  Frozen  APTIMA VIAL

Reject Due To

Transport tubes containing a cleaning swab or more than 1 swab Reject
No swab present in Aptima vial Reject

Reference Values

Only orderable as part of a profile. For more information see SCCGV / Chlamydia trachomatis and Neisseria gonorrhoeae, Self-Collect, Amplified RNA, Vaginal.

 

Negative

Day(s) Performed

Monday through Sunday

Report Available

1 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87491

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SCCTV C trach, RNA, SelfCollect, Vagina 43304-5

 

Result ID Test Result Name Result LOINC Value
621938 Chlamydia trachomatis amplified RNA 43304-5