Sign in →

Test Code SCCGV Chlamydia trachomatis and Neisseria gonorrhoeae, Self-Collect, Amplified RNA, Vaginal


Ordering Guidance


This test is only for self-collected patient specimens obtained in a healthcare setting. If collection was performed by the clinician, order CGRNA / Chlamydia trachomatis and Neisseria gonorrhoeae, Nucleic Acid Amplification, Varies.



Specimen Required


Specimen Type: Vaginal

Supplies: Aptima Vaginal Swab Self-Collection Kit (T1001)

Container/Tube: Aptima Multitest Swab

Specimen Volume: Swab

Collection Instructions:

1. Specimens must be collected in a healthcare setting by the patient using the Aptima Multitest Swab (provided in T1001 or available separately).

2. Provide patient with the Aptima Vaginal Swab Self-Collection Kit or Aptima Multitest Swab and Vaginal Swab Patient Collection Guide.

3. Instruct patient to collect the specimen following the instructions provided and then return swab to the healthcare professional once complete.

4. Once patient returns the specimen, ensure the tube is securely capped, and label tube with patient's entire name and collection date and time.

5. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred) and transport within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for up to 12 months.


Secondary ID

621937

Useful For

Detecting Chlamydia trachomatis and Neisseria gonorrhoeae using self-collected vaginal swabs collected by the patient in a healthcare setting

 

This test is not intended for use in medico-legal applications.

 

This test is not useful for the detection of other Chlamydia species.

Profile Information

Test ID Reporting Name Available Separately Always Performed
SCCTV C trach, RNA, SelfCollect, Vagina No Yes
SCGCV N gonor, RNA, SelfCollect, Vagina No Yes

Method Name

Transcription-Mediated Amplification

Reporting Name

Chlam/Gono RNA, SelfCollect, Vagina

Specimen Type

Varies

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) APTIMA VIAL
  Ambient  APTIMA VIAL
  Frozen  APTIMA VIAL

Reject Due To

Transport tubes containing a cleaning swab or more than 1 swab Reject
No swab present in Aptima vial Reject

Reference Values

CHLAMYDIA TRACHOMATIS

Negative

 

NEISSERIA GONORRHOEAE

Negative

Day(s) Performed

Monday through Sunday

Report Available

1 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87491

87591

87801-If appropriate for government payers

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SCCGV Chlam/Gono RNA, SelfCollect, Vagina 64017-7

 

Result ID Test Result Name Result LOINC Value
621938 Chlamydia trachomatis amplified RNA 43304-5
621939 Neisseria gonorrhoeae amplified RNA 43305-2